Effect of photovoltaic
installation power and façade glazing ratio on the energy performance of a
nursery building. |
2021 Vol. & No.: ahead-of-print |
ahead-of-print |
Marchwiński J. Kurtz-Orecka K. |
|
Tytuł artykułu nr 1
Effect of photovoltaic installation power and façade glazing ratio on the energy performance of a nursery building
Charakterystyka artykułu nr 1
Purpose: The aim of the research is to determine the influence of photovoltaic (PV) installation and the share of façade glazing on the energy profile of nursery buildings in the Baltic Sea region, as well as defining the most favorable configuration in terms of energy efficiency. Design/methodology/approach: The article provides comparative calculations of energy performance indicators (Ep, Ed, Eu) and CO2 emissions (mCO2) made for the defined model of the nursery. It includes calculations concerning energy performance of the building, depending on its PV power (0–60 kWp), PV efficiency (100 and 85%) and façade glazing ratio (GR = 25%, 50% and 75%). Findings: The results of the research indicate that an increase in the PV power exerts proportional impact on the reduction of the Ep and Ed indicators, as well as on the CO2 emissions. Only low GR values (25%) reduce the Eu indicator significantly. Decrease in high range of GR values (over 50%) does not provide proportional effects. In the variant: 60 kWp (100% efficiency) with GR = 25%, the biggest share (99.5%) of RES was obtained. This proves that the concept of energy independent nursery buildings is feasible and reasonable in the examined location. Practical implications: Designing buildings towards environmental neutrality requires laborious pre-design conceptual work before developing the right solutions. The set of results of the relationship between the variables of the building's envelope, energy performance indicators and the required involvement of active RES installations to achieve high energy performance of a building presented in the article is valuable. It allows for a preliminary decision of the direction of the design solutions selection in the design process of public utility buildings, such as nurseries. Thus, it may significantly shorten the pre-design analysis process for the location of the southern part of the Baltic Sea region. Originality/value: The novelty of the paper relies on examining the dependences between PV power and façade glazing ratio in terms of their influence on energy profile of nursery buildings.
Ilustracje
tak, kolorowe i czarno-białe
Język
angielski
Uwagi
szczegółowe informacje zawarto w tabelce